OBJECT = COLUMN NAME = EXTENDED_ISS_SCIENCE_HEADER BIT_DATA_TYPE = BINARY START_BYTE = 1 BYTES = 60 OBJECT = BIT_COLUMN NAME = "NAC/WAC" BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 1 BITS = 1 DESCRIPTION = "Camera that generated packet. Valid value: 0:NAC, 1:WAC." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = SUMMATION_MODE BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 2 BITS = 2 DESCRIPTION = "Camera summation mode. value: 01:1X1, 10:2X2 and 11:4X4." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = COMPRESSION BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 4 BITS = 2 DESCRIPTION = "Image compression mode. Value: 00:no compression, 01:lossless, 10:lossy, and 11:illegal." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = CONVERSION BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 6 BITS = 2 DESCRIPTION = "Conversion byte data type. Valid value: 00:no conversion, 01:12-8 bits by look up table, 10:least significant bits, 11: illegal type." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = CONTINUATION BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 8 BITS = 1 DESCRIPTION = "The first line of this packet is a continuation of a line begun in the previous packet. Valid value: 0:no cont,1:cont." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = HEADER_TYPE BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 9 BITS = 2 DESCRIPTION = "Indicates whether the header is standard or extended. valid value: 00:standard, 01:illegal, 10:illegal and 11:extended." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = GAIN BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 11 BITS = 2 DESCRIPTION = "Camera gain state. Valid values are 0,1,2, and 3." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = FILTER1 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 13 BITS = 4 DESCRIPTION = "Position of filter wheel one. There are 12 filters for narrow angle camera and 7 for wide angle camera." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = FILTER2 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 17 BITS = 4 DESCRIPTION = "Position of filter wheel two. There are 12 filters for narrow angle camera and 7 for wide angle camera." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = IMAGE_LINE BIT_DATA_TYPE = BINARY START_BIT = 21 BITS = 12 DESCRIPTION = "The line number of the first line in the packet. May refer to a partial line if the first line has been continued form the preceding packet." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = LAST_PACKET BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 33 BITS = 1 DESCRIPTION = "Indicates whether the current packet is the last for the image. Valid value: 0 - not the last, 1 - the last." END_OBJECT = BIT COLUMN OBJECT = BIT_COLUMN NAME = SPARE0 BIT_DATA_TYPE = "N/A" START_BIT = 34 BITS = 2 DESCRIPTION = "Unused." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = LOSSY_PARAMETERS BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 36 BITS = 13 DESCRIPTION = "Lossy parameter settings." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = SPARE1 BIT_DATA_TYPE = "N/A" START_BIT = 49 BITS = 1 DESCRIPTION = "Unused." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = CAL_LAMP BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 50 BITS = 1 DESCRIPTION = "The lamp state. Valid values are 0 for off and 1 for on." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = "LIGHTFLOOD/ERASE" BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 51 BITS = 1 DESCRIPTION = "CCD Flood Light and Erase mode. Valid are 0 for On and 1 for Off." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TCE_STATE BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 52 BITS = 2 DESCRIPTION = "The state of the temperature control electronics. Valid are 00 for Off, 10 for On, 01 for Off/Regulate and 11 for On/Regulate." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = OPTICS_HEATER_1 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 54 BITS = 1 DESCRIPTION = "Optics heater one indicator. Valid are 0 for On and 1 for Off." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = OPTICS_HEATER_2 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 55 BITS = 1 DESCRIPTION = "Optics heater two indicator. Valid are 0 for On and 1 for Off." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = "ANTI-BLOOMING" BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 56 BITS = 1 DESCRIPTION = "Anti-blooming state flag indicator. Valid are 0 for On and1 for Off." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = PREPARE_INDEX BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 57 BITS = 4 DESCRIPTION = "Prepare table index for the current image." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = RO_INDEX BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 61 BITS = 4 DESCRIPTION = "Index of the current readout table entry used for this image." END_OBJECT = BIT_COLUMN OBJECT = FIELDS NAME = TABLE_DATA OBJECT = BIT_COLUMN NAME = TABLE_ID BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 65 BITS = 4 DESCRIPTION = "The table data field commutates certain tables into the science header. This sub-field identifies the table being commutated. Valid are Exposure, Prepare and Read out." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = ENTRY BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 69 BITS = 12 DESCRIPTION = "The byte number of the table entry." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = ENTRY_CONTENTS BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 81 BITS = 16 DESCRIPTION = "The contents of the byte in the table." END_OBJECT = BIT_COLUMN END_OBJECT = FIELDS OBJECT = BIT_COLUMN NAME = IMAGE_NUMBER DATA_TYPE = BINARY START_BIT = 97 BITS = 16 DESCRIPTION = "This field holds the image number since Power On Reset (POR). A zero here indicates that no images have been returned since POR. Value starts at 1 and proceeds to 32767 and recycles to 1." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_1 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 113 BITS = 16 DESCRIPTION = "HK50V_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_2 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 129 BITS = 16 DESCRIPTION = "HK30V_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_3 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 145 BITS = 16 DESCRIPTION = "HK28V_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_4 DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 161 BITS = 16 DESCRIPTION = "HK15V_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_5 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 177 BITS = 16 DESCRIPTION = "HKMIN15V_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_6 DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 193 BITS = 16 DESCRIPTION = "HK5V_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_1 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 209 BITS = 16 DESCRIPTION = "CCD_MON." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_2 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 225 BITS = 16 DESCRIPTION = "HKOPT1_TEMP_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_3 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 241 BITS = 16 DESCRIPTION = "HKOPT2_TEMP_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_4 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 257 BITS = 16 DESCRIPTION = "HKOPT3_TEMP_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_5 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 273 BITS = 16 DESCRIPTION = "HKOPT4_TEMP_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_6 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 289 BITS = 16 DESCRIPTION = "HKEFC1_TEMP_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_7 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 305 BITS = 16 DESCRIPTION = "HKEFC2_TEMP_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TEMPERATURE_8 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 321 BITS = 16 DESCRIPTION = "HKME3_TEMP_TEL." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = CURRENT BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 337 BITS = 16 DESCRIPTION = "Voltage indicating instrument current(ISS_CSENS)." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = TRIGGER DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 353 BITS = 16 DESCRIPTION = "The command id of the last command triggered." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = COMMAND BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 369 BITS = 16 DESCRIPION = "Number of commands since POR. The number starts at 0 and proceeds to 32767 and recycles to 0." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = UPLOAD BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 385 BITS = 16 DESCRIPTION = "The number of the current upload. Starts with 1 and proceeds to 32767 then recycles to 1." END_OBJECT = BIT_COLUMN OBJECT = FIELDS NAME = SOFTWARE OBJECT = BIT_COLUMN NAME = UPLOAD_EMPTY BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 401 BITS = 1 DESCRIPTION = "Indicates whether upload memory is empty. Valid value are 0 for not empty and 1 for empty." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = COLD_START BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 402 BITS = 1 DESCRIPTION = "Indicates whether a cold start occurred in last hkp period. Valid values are 0 for not cold start and 1 for cold start." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = WARM_START BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 403 BITS = 1 DESCRIPTION = "Indicates a warm start occurred in last hkp period. Valid values are 0 for not warm start and 1 for warm start." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = LOSSY_TEST BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 404 BITS = 1 DESCRIPTION = "Indicates whether the lossy self-test is okey. Valid values are 0 for not okey and 1 for okey." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = UPLOAD_LOADING BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 405 BITS = 1 DESCRIPTION = "Indicates if upload memory is loading. Valid values are 0 for not loading and 1 for loading." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = ORDER BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 406 BITS = 1 DESCRIPTION = "Indicates whether the NAC or the WAC is being read out first. Valid values are 0 for NAC and 1 for WAC." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = SPARE BIT_DATA_TYPE = "N/A" START_BIT = 407 BITS = 2 DESCRIPTION = "Not used." END_OBJECT = BIT_COLUMN END_OBJECT = SOFTWARE OBJECT = BIT_COLUMN NAME = EXPOSURE BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 409 BITS = 8 DESCRIPTION = "An index into the exposure table for the current image. valid value are from 0 through 63." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_7 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 417 BITS = 16 DESCRIPTION = "VREF_HI" END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = VOLTAGE_8 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER START_BIT = 433 BITS = 16 DESCRIPTION = "VREF_HI" END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = SPARE2 BIT_DATA_TYPE = "N/A" START_BIT = 449 BITS = 32 DESCRIPTION = "Not used." END_OBJECT = BIT_COLUMN END_OBJECT END